Relays Explained

Relays Explained

Relays are widely used in electrical applications where one circuit is to be energized or turned "on" by the presence of a voltage, provided by another circuit. An example of this is when an Otter switch controls a triggering voltage which indicates that the fans should turn on.

The "switch" in a relay is controlled by an electromagnet. The magnet is used to close the switch contacts on the main circuit. The "switch" part of the relay is usually very heavy duty, while the electromagnet draws little current. This allows a very low current signal to control a very high current device. A relay can be triggered with an electrical pulse as small as 150 milliamps. The switched output can be as high as 30 or 40 amps.

Relays can be "normally closed", "normally open", or both. Normally closed means that when the magnet isn't energized, the switch contacts are closed, and therefore the circuit is on. Normally open means the opposite: when the relay isn't energized, the switch is off. Bosch relays usually have both an "87" and an "87a" contact, which are respectively NO and NC. This design is also called "single pole, double throw", or SPDT for short. The following diagram should make this clearer.


Relay unpowered




Bosch Relay Base Diagram


Relay powered

Connections
The terminals of a relay are defined as follows:

  • 30 is the common or input voltage to be switched.
  • 87a is the normally closed connection. This terminal is hot when the relay isn't energized, it is unpowered the relay is energized.
  • 87 is the normally open connection. Powered only when the relay is energized.
  • 85 is connected to the ground of the triggering voltage.

  • 86 is connected to the positive 12V of the triggering voltage.
Bosch to Lucas Terminal Mapping
Typical Bosch Relay
Typical Lucas Relay



Fan Application
Note: Basic application.

Source
Fan Application


Note: Advanced version. Fan grounds when freewheeling. Fan is on common post.